Relationship Between Artificial Airway Humidification Amount and Different Sputum Viscidity in Patients with Tracheal Incision

Zhenhong Wei
2010-01-01
Abstract:Objective To find out the relationship between the artificial airway humidification amount and sputum viscidity in patients with tracheal incision.Methods Total 270 case times of patients undergoing tracheal incision were randomly selected,They were divided into three groups of grade Ⅰ,Ⅱ,and Ⅲ according to the viscidities of the sputum.And each group was further subdivided into three subgroups according to the dose of airway humidification.At the 24th hours the change trend was observed,and at 48th hours the humidification result was evaluated according the criteria of classifying the viscidities of the sputum.The test of χ2 was used for statistical analysis.Results The best humidification amount for artificial airway humidification was 6 ml/h,12 ml/h,and 16 ml/h respectively for gradeⅠ,gradeⅡ,and grade III.sputum viscidity.Conclusion The needed amount of humidification is different according to different sputum viscidity.