Abstract:Against the safety of the tendon anchorage zones during the tensioning stage,large-tonnage tendon technology was adopted in nuclear power plants containment.With the method of load transfer performance,experimental study on OVM15R-37K-special bearing plate of containment vessel for nuclear power station were tested to investigate the load transfer behaviors of post-tensioned concrete anchorage zones,including ultimate loads,strain,crack width,while some relative parameters were studied.The results of test and analysis show that the ultimate loads of specimens can reach 1.2Fpk;the grid reinforced bar can improve the cracking load and substantially reduce the crack width;the stresses of anchorage devices are far below the yield limit of steel in the tensioning stage.The results of this experiment promote the application of domestic prestressed anchorage in nuclear power station.
What problem does this paper attempt to address?