[Pilot-Scale Study on Treatment of Municipal Sewage by Moving-Bed Biofilm Reactor with the Hydrophobically Modified Polyurethane Cubes As Biofilm Carriers].
Yu-Xiao Wang,Xiu-Qin Kong,Quan Feng,Hai-Tao Lu,De-Yuan Wang,Li-Ming Tang,Xin-Hui Xing
2012-01-01
Abstract:The carrier is the key influencers in moving bed biofilm reactor( MBBR), in this paper, a pilot scale apparatus was set up for treating municipal wastewater using modified cubic polyurethane carriers. For MBBR, the capacity of 3-3.5 t x d(-1), hydraulic residence time of 7-8 h, under the condition of continuous feed water (COD:140-280 mg x L(-1), NH4+ -N:30-50 mg x L(-1), TN: 45-65 mg x L(-1), TP:2.5-4.0 mg x L(-1)), the speed of biofilm formation and removal effects of COD, nitrogen and phosphorus were studied. After 140 days, the results showed that the formation of biofilm on the carrier was very quickly under 24-28 degrees C, and obtained stable treatment effect about 6 days. The COD, NH4+ -N, TN, TP average removal rates were 70%, 97%, 70%, 39%, respectively. As the temperature gradually decreased to about 12 degrees C, a high NH4+ -N removal rate (97%) could still be maintained, which indicating that the modified carrier can be achieved a high nitrification rate at low temperature.