Analysis of the Effect of Characteristic Parameters and Operating Conditions on Exergy Efficiency of Alkaline Water Electrolyzer

Shun-Liang Ding,Bin Guo,Song Hu,Junjie Gu,Fuyuan Yang,Yangyang Li,Jian Dang,Biao Liu,Jugang Ma
DOI: https://doi.org/10.2139/ssrn.4065639
2022-01-01
SSRN Electronic Journal
Abstract:In this paper a thermodynamics-electrochemical model of AWE is established, then this model is applied to detailly analyze the influences of characteristic parameters (electrode conductivity, distance between the electrode and diaphragm, diaphragm porosity and tortuosity, electrolyte concentration, bubble coverage) and operating conditions (temperature and pressure) on over-potential and exergy efficiency of AWE. Analysis results show that activation over-potential, compared with ohmic over-potential, presents more significant influence on the cell voltage and exergy loss. Ohmic over-potential changed most obviously with current density under the condition of 358K and 30wt% KOH concentration. Diaphragm resistance accounts for the largest proportion of total ohmic resistance exergy loss, followed by electrolyte and bubbles, and electrode resistance can be almost ignored. By quantifying and comparing the effect of each parameter on exergy efficiency, it is found that the diaphragm porosity has the most obvious effect on exergy efficiency among each characteristic parameter, the effect of electrode gap is the second in impact, the effect of bubble coverage is less important, but studies related to it are valuable and the effect of electrode conductivity can be largely ignored. The influence of temperature on exergy efficiency is more significant than that of pressure in operating conditions.