Determining Moist-Based Ventilation Rates for Residential Buildings with Low-Infiltration in China: A Preliminary Discussion

Shengyi Tang,Wei Ye,Xing Su,Xu Zhang
DOI: https://doi.org/10.1007/978-981-13-9520-8_11
2020-01-01
Abstract:There is a growing concern over whether ventilation rates (VRs) for building are health-based. For example, moisture-related problems, e.g., molds and mites, can pose adverse health effects on occupants. However, ventilation-induced moist indoors is an overlooked issue in China. In this paper, the effects of VRs, as well as typical building characteristics, on indoor humidity levels were investigated using EnergyPlus. 1008 residential models (with low infiltration, and various ventilation and climate scenarios) were simulated. Generally-agreed non-healthy humidity levels were used to analyze health risks. The results showed that, first, buildings in two hot summer zones were at risk of high indoor humidity, while buildings in two cold zones might experience higher risks of low humidity. Second, higher the VRs, higher the risk of low humidity in cold zones, and higher the risk of dampness in hot summer zones. Third, it can be easier to be more humid indoors for small-size, top-floor, or north orientation residences in China.
What problem does this paper attempt to address?