Impact of Various Ventilation Modes on IAQ and Energy Consumption in Chinese Dwellings: First Long-Term Monitoring Study in Tianjin, China

Lei Zhao,Junjie Liu,Jianlin Ren
DOI: https://doi.org/10.1016/j.buildenv.2018.06.057
IF: 7.093
2018-01-01
Building and Environment
Abstract:People typically spend many hours a day inside their homes. Outdoor PM2.5, indoor décor, and the activities of residents worsen indoor air quality. Natural ventilation, natural ventilation with a portable air cleaner (PAC), and mechanical ventilation are some of the main ventilation modes. However, limited data are available on the actual performance of different ventilation modes. We conducted a one-year on-site program of measurement in six apartments in Tianjin, China. The results showed that indoor air quality was affected by both outdoor particle concentration and indoor activities (walking, cooking, etc.). Natural ventilation alone cannot guarantee indoor air quality. A mechanical ventilation system could reduce the duration of high indoor particulate pollution periods to some extent; however, whole year monitoring revealed that it was not effective in increasing healthy time ratios. Reduction in CO2 concentrations above the standard levels through mechanical ventilation is 22.3% more than that through natural ventilation dwellings. Natural ventilation with a portable air cleaner can remove mass particulate pollution rapidly and maintain good indoor air quality with long-time operation. This study is expected to contribute towards the improvement of indoor air quality and the health of residents.
What problem does this paper attempt to address?