The Methodologies and Instruments of Vehicle Particulate Emission Measurement for Current and Future Legislative Regulations

Yoshinori Otsuki,Hiroshi Nakamura,Masataka Arai,Min Xu
DOI: https://doi.org/10.1088/0957-0233/26/9/092002
2015-01-01
Abstract:Since the health risks associated with fine particles whose aerodynamic diameters are smaller than 2.5 ?m was first proven, regulations restricting particulate matter (PM) mass emissions from internal combustion engines have become increasingly severe. Accordingly, the gravimetric method of PM mass measurement is facing its lower limit of detection as the emissions from vehicles are further reduced. For example, the variation in the adsorption of gaseous components such as hydrocarbons from unburned fuel and lubricant oil and the presence of agglomerated particles, which are not directly generated in engine combustion but re-entrainment particulates from walls of sampling pipes, can cause uncertainty in measurement. The PM mass measurement systems and methodologies have been continuously refined in order to improve measurement accuracy. As an alternative metric, the particle measurement programme (PMP) within the United Nations Economic Commission for Europe (UNECE) developed a solid particle number measurement method in order to improve the sensitivity of particulate emission measurement from vehicles. Consequently, particle number (PN) limits were implemented into the regulations in Europe from 2011. Recently, portable emission measurement systems (PEMS) for in-use vehicle emission measurements are also attracting attention, currently in North America and Europe, and real-time PM mass and PN instruments are under evaluation.
What problem does this paper attempt to address?