Bioeguivalent Study of Two Glipizide Capsules in Human Plasma

Xia Chun-hua,Lixin Li,Zhang Xin-jing,Yanyan Li
2005-01-01
Abstract:Objective To establish a HPLC method for the determination of two glipizides and their bioequivalence in male volunteers. Method 1.0 mL serum sample was added to C_(18) cartridges,and then washed with 1.0 mL 20% methanol solution.The cartridge was eluted with methanol.The residue from the eluate evaporated to dryness at 60 ℃ was dissolved in methanol and injected into a Diamonsil ODS column(4.6 mm×150 mm, 5 μm).The mobile phase was purified water(pH value=3.65,adjusted with acetic acid)-acetonitrile(51∶49),the flow rate 1.0 mL·min~(-1),and the detect wavelength 275 nm.A single oral dose of 10 mg of test capsule or reference capsule was given to 18 volunteers in randomized in two groups with crossover design. Results The linear range was within 20-960 ng·mL~(-1),r= 0.999 9.The limit of detection was 20(ng·mL~(-1)).The recovery rate was 98.2%-105.7%.Their within-day precision RSD and between-day precision RSD were less than 10%.The main pharmacokinetic parameters had no significant difference between two preparations. Conclusion This method is sensitive,specific and suitable for the determination of glipizide concentration in human plasma.The two preparations are bioequivalent.
What problem does this paper attempt to address?