Gamma Ray Absorption of Cylindrical Fissile Material with Dual Shields

Kan Wu,Chen-Yan,Tian,Dongfeng Xie,Wood-Hi Cheng,Yi-Ying,Adam Huang,Yongyi,Jiwen Lu,Fu-quan,Jinfu Yang,Fujia
2005-01-01
Abstract:This work analyzed the gamma ray attenuation effect from the self-absorption and shield attenuation per-spectively. An exact mathematical equation was given for the geometric factor of the cylindrical fissile material with dual shields. In addition, several approximation approaches suitable for real situation were discussed, especially in the radial and axial directions of the cylinders, since the G-factors have simple forms. Then the space distribution patterns of the G-factor were analyzed based on numerical result and effective ways to solve the geometric informa-tion of the cylindrical fissile material, the radii and the heights, were deduced. This method was checked and verified by numerical calculation. Because of the efficiency of the method, it is ideal for application in real situations, such as nuclear safeguards, which demands speed of detection and accuracy of geometric analysis.
What problem does this paper attempt to address?