Establishing Curve for Measuring Strength to Detect Compression Strength with Resilience Method for Ningxia Municipality

Rui Chen
2004-01-01
Abstract:In order to change the condition that there was no applied strength analysis curve used in Ningxia Municipality, an experimental investigation, which took into account the local physical feature and aimed at detecting strength by resilience method, was made for C10~C50 concrete test cube with ZC3-A type concrete resiliometer. Analysis and comparison was made with a great variety of modes so that a preferred curve formula was formed, i.e.(=0.0254 4Rm2.0106×10-0.0359×Li). The measuring accuracy meets the requirement for controlling the quality of concrete, so the curve can act as a standard one for Ningxia Municipality.