Model-Based Severity Monitoring for Interturn Short Circuit Faults in Symmetrical Six-Phase PMSMs Using Subspace Current Residuals

Jianhui Hu,Huidong Wang,Yong Li
DOI: https://doi.org/10.1109/tpel.2023.3314652
IF: 5.967
2023-01-01
IEEE Transactions on Power Electronics
Abstract:This article proposes a novel model-based method for severity level monitoring of interturn short-circuit faults (ISCFs) using the xy subspace current residuals in symmetrical six-phase permanent magnet synchronous machines. For six-phase control system, the six-phase currents are usually mapped onto the dq and xy subspaces by vector space decomposition. The behavior in each subspace is affected by ISCF. In order to avoid PM flux linkage error reducing the performance of model-based method, the fault indicator is generated using the xy subspace current residuals. The proposed method has a high signal-to-noise ratio by extracting a fundamental signal instead of the second harmonic. Moreover, the proposed fault indicator can be obtained by simple signal processing without the use of spectral analysis tools or lots of filters. Experimental results show the effectiveness of proposed method for different fault severities and operating conditions.
What problem does this paper attempt to address?