Inter-turn short-circuit fault detection with high-frequency signal injection for inverter-fed PMSM systems

Zheng Xu,Jianzhong Zhang,Zakiud Din,Yongbin Wu,Ming Cheng
DOI: https://doi.org/10.1007/s43236-022-00585-w
IF: 0.913
2023-01-13
Journal of Power Electronics
Abstract:This paper develops an online inter-turn short-circuit fault (ISF) detection method for inverter-fed permanent magnet synchronous machine (PMSM) systems. A high-frequency (HF) mathematical model of a PMSM with an ISF is established. Based on the presented HF model, the HF responses of the PMSM with various severity of ISF under HF voltage injection are analyzed in detail, where both the short-circuit ratio and the fault resistance are considered to evaluate the fault severity. In the proposed fault diagnosis method, the amplitude of the HF negative-sequence component is used to determine the fault severity, and the initial phase is used to locate the position of the faulty phase. The simulation and experimental results verify the effectiveness of the proposed method.
engineering, electrical & electronic
What problem does this paper attempt to address?