Online Detection and Classification of Interturn and Groundwall Insulation Aging Based on Broadband Common-Mode Impedance Spectrum

Dayong Zheng,Geye Lu,Yang Wu,Qinghao Zhang,Pinjia Zhang
DOI: https://doi.org/10.1109/tie.2023.3265024
IF: 7.7
2024-01-01
IEEE Transactions on Industrial Electronics
Abstract:Online condition monitoring for stator insulation is important for reliable operation of electrical machines. Recent studies show that the method based on the common-mode (CM) impedance spectrum is effective in online monitoring of the overall insulation aging condition. However, it is difficult to detect the interturn aging condition since the groundwall insulation aging has a similar impact on the monitoring results. In this article, the relationship between the change in the CM impedance spectrum and the stator winding insulation aging is studied based on the per-turn-unit broadband CM stator winding model. The dataset of impedance spectrum for different insulation aging conditions is built using this model. Multiple points in the impedance spectrum are used to detect the change in the interturn and groundwall insulation parameters separately. The online experimental results prove the validity of the proposed method. The proposed method can detect the insulation aging condition with the error about 6%. There is no other method that can quantify the aging degree of interturn insulation in the presence of groundwall insulation aging. Compared with the black-box data-driven methods, the proposed method is based on a model with clear physical meaning, which makes the results more reliable.
What problem does this paper attempt to address?