Determing Ination of Phenols Compounds in Drinking Water by Double-Column Solid Phase Extraction-HPLC

Xiang Li
2011-01-01
Abstract:A solid phase extraction and reversed phase high performance liquid chromatographic(RP-HPLC) method was introduced for the separation and determination of phenols in drinking water sample.Water sample was purified and concentrated by C18 and GDX-502 cartridges.The analytical column of HPLC was Shim-pack VP-ODS with amobile phase of methanol(include 1%HAc,v/v)and water(include 1%HAc,v/v)at a flow rate of 1 mL/min,temperature of column at 35 ℃ and wavelength at 280 min.The results show that the detection limit of the method is 0.02-18 μg/L for these phenol compounds.the average recovery is 73.7%~107.6% with precision of 2%~13.2%RSD(n=3).The method has been applied to the determination of trace phenol compounds in practical drinking water samples with the advantages of simplicity,less organic solvent consumption and high efficiency.