Research of CCM Boost PFC with Enabling Window Control

Dehong Xu
IF: 5.967
2011-01-01
IEEE Transactions on Power Electronics
Abstract:Continous current mode(CCM) Boost power factor correction(PFC) has been widely used because of its high input power factor and simple control.But it suffers from efficiency decrease under the light load or the low in-put voltage work condition.A novel enabling window control is proposed to improve the efficiency of Boost PFC,espe-cially under the light load or the low input voltage work condition.To improve the efficiency,lower switching frequen-cy is used in the selected window area to reduce the switching loss of MOSFET.The principle and design of proposed method are presented,furthermore,the validity of the proposed method is verified by experimental results which ob-tained from a 500 W prototype.
What problem does this paper attempt to address?