LOCKING PLATE SYSTEM IN THE TREATMENT OF PERIPROTHETIC FRACTURE FOLLOWING INTRAMEDULLARY NAIL TREATMENT FOR FEMORAL INTERTROCHANTERIC FRACTURE

Qian Wang
2014-01-01
Abstract:Objective To discuss the feasibility of using the locking plate system(LPS)in the treatment of fracture around the intramedullary nail after treatment of femoral intertrochanteric fracture(FITF). Methods By applying LPS,seven patients with fracture around the intramedullary nail after surgry for FITF(fracture around the prosthesis after surgery of prosthetic replacement of joint,Vancouver type-B1fracture)were divided into two groups:removal intramedullary nail group and retention group.A postoperative follow up was conducted for more than 12 months to observe the fracture healing and the recovery of limb function. Results The fractures in the seven patients healed well and returned to walk. Conclusion It is a wise choice to use locking plate system for subsequent peri-prothetic fracture(Vancouver type-B1)following intramedullary treatment for intertrochanteric fracture,especially for those with previously incompletely-healed fracture.The initial main nail had to be reserved.The fracture of intramedullary side can be fixed by unicortical and/or bicortical screws.The titanium cables around the stem can be used to strengthen the fixation.