Catalytic Oxidative Degradation of 0-Nitrochlorobenzene in Sewage Using Ag/TiO2.

Du Xi,Qin Wang,Jun Du,Jian-Min Guo,Hong Li
2010-01-01
Abstract:To investigate the oxidation of sodium percarbonate (SPC)for 0-nitrochlorobenzene on Ag/TiO2,with sodium percarbonate as oxidant,self-prepared Ag/TiO2 catalysts were used to catalyze degradation reaction of 0-nitrochlorobenzene and the effect of reaction conditions including catalyst variety,catalyst dosage,oxidation dosage,concentration of substrate, reaction temperature and adding inorganic salt on degradation was studied. Results indicated that the activity of Ag/TiO2 catalyst was rather high on condition of catalyst dosage 1.57×10-6mol,substrate concentration 6.35×10-4mol/L and SPC 3.18×10-3mol, 40℃,the degradation rate could reach 94%. Reaction could be promoted by alkali halide and alkaline halide addition,gaining degradation rate of 99% accordingly,which indicated that 0-nitrochlorobenzene in sewage could be degraded effectively. The conceivable mechanism was posed to explain the process of oxidation.
What problem does this paper attempt to address?