A 5-to-8-ghz Wideband Miniaturized Dielectric Spectroscopy Chip with ≪inline-Formula> ≪tex-Math Notation="latex">$i/q$ ≪/tex-Math> ≪/inline-Formula> Mismatch Calibration in 65-Nm CMOS

Shunli Ma,Ning Li,Junyan Ren
DOI: https://doi.org/10.1109/tvlsi.2018.2819702
2018-01-01
IEEE Transactions on Very Large Scale Integration (VLSI) Systems
Abstract:This paper presents a fully integrated broadband biosensor chip for miniaturized dielectric spectroscopy (DS). The proposed biosensor chip consists of wideband exciting signal source and high sensitivity receiver. The exciting signal source consists of a wideband phase-locked loop (PLL) and output drivers. The wideband receiver is composed of low noise amplifier, mixer, and output buffers. The proposed receiver with in-phase (I) and quadrature-phase (Q) signals mismatch calibration measures the frequency-dependent S21 magnitude and phase of a microfluidic dielectric sensor. The DS system implements a modified frequency response analysis by converting the biosensor response signal from the RF excitation frequency to low frequency using a passive mixer. Dielectric measurements results of ethanol with the proposed biosensor chip in the range of 5-8 GHz are in excellent agreement (error <;1%) with theoretical values. The chip is fabricated in 65-nm CMOS process. The total power consumption is 18 mW with 1.2-V supply.
What problem does this paper attempt to address?