Influence of the Online Closure Loading on the Eddy Current Testing Signals of Closed Fatigue Crack
Wenlu Cai,Zheng Xie,Shejuan Xie,Cuixiang Pei,Yong Li,Zhenmao Chen
DOI: https://doi.org/10.3233/jae-162114
2016-01-01
International Journal of Applied Electromagnetics and Mechanics
Abstract:In this study, the strategy to simulate a real stress corrosion crack (SCC) with a closed fatigue crack (FC) in view of eddy current testing (ECT) is investigated. An online four-point bending ECT device is designed and fabricated to provide the closure loading for a plate specimen and to enable online ECT measurements. The amplitudes of ECT signals due to FCs closed with different closure loads are measured. The experimental results show that the amplitudes of ECT signals due to closed FCs change regularly with the applied closure loads, and the ECT signal will recover to the initial state once the closure loading is released. The experimental results also reveal that, instead of the residual plastic strain, the online closure loading can make the FC conductive and a larger load leads to bigger crack conductivity. Through inverse analysis of the measured ECT signals, it is found that the conductivity in the crack region can reach to as big as 45% of the base material conductivity due to a large closure load. The results of this work demonstrated the feasibility positively to simulate a SCC with an online closed FC specimen for ECT measurement.