Optimization Study of Operation Parameters for Extracting Cu^2+ from Sulfuric Solution Containing Co^2+ with LIX984N in a Laminar Microchip

Bi-quan Xiao,Feng Jiang,Jin-hui Peng,Shao-hua Ju,Li-hua Zhang,Shao-hua Yin,Li-bo Zhang,Lei Xu,Shi-hong Tian
DOI: https://doi.org/10.1007/s13369-017-2495-1
IF: 2.807
2017-01-01
Arabian Journal for Science and Engineering
Abstract:Copper and cobalt usually coexist in the leachate of waste lithium ion batteries, sea nodules and other copper ore or by-product. Conventional methods for the separation of copper and cobalt hardly avoid some defects, such as longer extraction time, co-extraction and too many stages. In this paper, a microfluidic extraction procedure for simultaneously separating copper (Cu^2+) and cobalt (Co^2+) ions in a microchannel was investigated. In addition, some key operation parameters, such as initial pH, volume flow rate and extractant concentration, were optimized by a method of response surface methodology (RSM). The result showed that under the optimized operation parameters of initial pH of 2.5, volume flow rate of 0.035 mL min^-1 and extractant concentration of 17.36
What problem does this paper attempt to address?