Estimated calculation of expiratory time constants for expiratory resistance evaluation during noninvasive positive pressure ventilation

陈宇清,袁越阳,张海,李锋,李兴旺
DOI: https://doi.org/10.3760/cma.j.cn115668-20191220-00190
2020-01-01
Abstract:Objective:To evaluate the expiratory resistance (R exp) in different lung mechanics models during noninvasive positive pressure ventilation (NPPV) according to estimated calculation of expiratory time constants (τ E) . Methods:ASL 5000 mechanical lung simulator was used to mimic a semi-recumbent subject with a body mass of 65-70 kg, either being a healthy adult or a patient with high airway resistance with or without low thoraco-pulmonary compliance (mixed ventilatory disorder) . The system settings included: compliance (C rs) , 25 (for mixed ventilatory disorder) or otherwise 50 ml/cmH 2O (1 cmH 2O=0.098 kPa) ; R exp, 5 (for healthy adult) or otherwise 20 cmH 2O·L -1·s -1; inspiratory time, 1.6 s; respiratory rate, 15 times/min. The Respironics V60 ventilator was set to operate in S/T mode with a positive end-expiratory pressure (PEEP) of 5 cmH 2O. Inspiratory pressure was adjusted to maintain a tidal ventilator output (V T) of 5, 7 and 10 ml/kg, respectively, and a backup ventilation frequency of 10 times/min. Ventilation parameters[inspiratory tidal volume (V TI) , expiratory tidal volume (V TE) , system leakage (V leak) , peak inspiratory pressure (PIP) , peak inspiratory flow (PIF) , peak expiratory flow (PEF) and the expiratory flow at 75% expiratory tidal volume (TEF 75) ] were recorded at the V leak level of 25-28 L/min. Thereby τ E, C rs and R exp were estimated and evaluated. Results:With increasing V TI and V TE, V leak, PIP, PIF and PEF gradually increased. At the V T of 10 ml/kg, the PIP in the mixed ventilatory disorder model reached 28 cmH 2O, and the PIF and PEF values in all of the three lung mechanics models were nearly two times higher than those at the V T of 5 ml/kg (all P<0.01) . During expiration, the PEF gradually decreased with the discharge of V TE. When V T was 7-10 ml/kg, there was no statistically significant difference between TEF 75 and PEF (all P>0.01) . The level of V T did not interfere obviously with the calculated τ E value in the high airway resistance model. In all of the three lung mechanics models, the estimated C rs values gradually decreased with increasing V T. Under high airway resistance, the error of calculated C rs value was <20% when the V T was 7 ml/kg. With increasing ventilation support, the measured R exp gradually increased in all of the three lung mechanics models. When the V T was 7 ml/kg, the difference between the measured R exp and the preset value became even lower (<10%) . Conclusion:Estimated calculation of τ E may allow for continuous monitoring of R exp in patients on NPPV support without interference of spontaneous breathing. Proper selection of V T (7 ml/kg) can be the key to reduce the measurement error while ensuring effective ventilation support.
What problem does this paper attempt to address?