A novel liquid-level measurement method based on electromagnetic acoustic guided waves.

Fulu Liu,Jiyao Li,Jun Long,Lijun Xu,Yuedong Xie
DOI: https://doi.org/10.1109/I2MTC53148.2023.10175983
2023-01-01
Abstract:In this paper, we propose a non-contact liquidlevel measurement method based on guided waves implemented by an electromagnetic acoustic transducer (EMAT). Two EMATs with a center-to-center distance of 350 mm are placed on the aluminum alloy plate of the tank, and a meander-line-coil carrying a 403 kHz signal is used to measure the liquid level without contacting the liquid. Out-of-plane and in- plane displacements were calculated to optimize the parameters of the EMAT coils, and the arriving time of the echoes from the liquid surface is used to estimate the liquid-level. The detection sensitivity of 1.21 mu s/mm and 2.42 mu s/mm were achieved for once-reflection mode and twice-reflection mode, respectively, and the relative error of the liquid-level measurement is less than 4%. Based on these results, the proposed method can be used for liquid-level measurement, and provides a potential to measure the fluid properties such as density, acoustic impedance and so on.
What problem does this paper attempt to address?