Simultaneous Measurement of Liquid Level and Refractive Index Based on a Sandwich Multimode Optical Fiber Structure
Xiangwen Yang,Binbin Luo,Decao Wu,Xue Zou,Shenghui Shi,Fuming Zhou,Chenglei Fan,Qianguang Hu,Mingfu Zhao
DOI: https://doi.org/10.1016/j.optlastec.2023.109856
2024-01-01
Abstract:A liquid level and refractive index double-parameter sensor made by sandwiching the graded-index multimode fiber (GIMMF) between two pieces of very short stepped-index multimode fibers (SIMMFs) spliced with input -single-mode fiber (SMF) and output-SMF, respectively, was proposed. The sensing principle and the interfer-ence spectrum characteristics of the SIMMF-GIMMF-SIMMF structure were theoretically analyzed in detail. The effects of the length of GIMMF on refractive index and liquid level sensitivity were investigated. The experi-mental results showed that due to the special refractive index distribution of GIMMF, the transmission spectrum of the sensor was the superposition of the spectrum between the GIMMF cladding modal interferometer (CMI) and the interference spectrum between the GIMMF fiber core modes and the low-order cladding modes. When the length of GIMMF is 3 cm, the wavelength of CMI dips was highly sensitive to the surrounding refractive index and liquid level but nearly independent of the surrounding temperature. In the range of 0-30 mm liquid level, the maximum level sensitivity of the sensor was 0.88 nm/mm. The maximum refractive index sensitivity of the sensor was 315.21 nm/RIU in the refractive index range of 1.3162 to 1.3564, and a temperature sensitivity of only 2.71 pm/celcius in the range of 30 to 45 celcius. Based on the differences of liquid level and refractive index sensitivity for two CMI dips, a group of function relation which could detect liquid level and refractive index simultaneously was established. The proposed sensor has the advantages of high sensitivity, small measurement error, stable performance, and simple fabrication, and has potential application prospect in fuel storage and chemical liquid level measurement.