Active Vibration Control for a Large Annular Flexible Structure Via a Macro-Fiber Composite Strain Sensor and Voice Coil Actuator
Zengyong An,Minglong Xu,Yajun Luo,Chengsong Wu
DOI: https://doi.org/10.1142/s1758825115500660
IF: 3.5
2015-01-01
International Journal of Applied Mechanics
Abstract:Large annular flexible structures (LAFS) are typical antenna structures for satellites. This structure can significantly increase antenna aperture and effectively improve communication accuracy with minimum addition of mass. LAFS have become mainstream for large aperture antenna structures. However, they have disadvantages, such as low natural frequencies, low damping ratio, and low stiffness. They easily suffer from low frequency, longtime and modal responses. Therefore, the vibration control of LAFS is very important. This study proposes a novel active vibration control method using macro-fiber composite (MFC) as a sensing unit, a voice coil actuator and a PD-fuzzy control algorithm. The MFC sensor can measure a minimum strain of 10-8 m/m. The voice coil actuator generates a displacement and driving force. Based on the feedback signal from the MFC sensor, the PD-fuzzy control algorithm controls the voice coil actuator. A dynamic model of LAFS was established, and its characteristics analyzed. A theoretical model for the voice coil actuator and MFC sensor were established, and the corresponding governing equations derived. An experimental system was set up. The results demonstrated that the novel active vibration control method has good performance. This active vibration control method can control vibration at ultralow frequencies and requires no additional stiffness.