A Cable Hybrid Type Defect Localization Method Based on Frequency Domain Reflectometry

X. Lu,H. Zhang,H. Mu,J. Tian,D. Zhang
DOI: https://doi.org/10.1049/icp.2022.0100
2021-01-01
Abstract:Early detection and elimination of cable defects is very important to improve the reliability of cable operation. Traditional time-domain reflection (TDR) localization method unable to locate latent defects due to the rising edge of the pulse signal. In recent years, some scholars have started local defect localization research based on frequency domain reflectometry (FDR). This paper proposes a method for diagnosing hybrid type cable defects based on frequency domain reflectometry. Simulation and field test were carried out to analyse the aging and abrasion defects on the same cable to illustrate the reliability of the positioning algorithm when mixed types of defects occur. The simulation and experimental results correspond well, which illustrates that when hybrid type of defects occur in the same cable, FDR can locate the defects and the location accuracy of simulation is within 0.5%, and the experimental test is within 0.3%.
What problem does this paper attempt to address?