Numerical Study of the Deep Removal of R134a from Non-Condensable Gas Mixture by Cryogenic Condensation and De-Sublimation

Hongbo Tan,Boshi Shao,Na Wen
DOI: https://doi.org/10.1016/j.cjche.2023.02.008
2023-01-01
Abstract:Nowadays,the limits on greenhouse gas emissions are becoming increasingly stringent.In present research,a two-dimensional numerical model was established to simulate the deep removal of 1,1,1,2-tetrafluoroethane(R134a) from the non-condensable gas(NCG) mixture by cryogenic condensation and de-sublimation.The wall condensation method was compiled into the Fluent software to calculate the condensation of R134a from the gas mixture.Besides,the saturated thermodynamic properties of R134a under its triple point were extrapolated by the equation of state.The simulation of the steam condensation with NCG was conducted to verify the validity of the model,the results matched well with the experimental data.Subsequently,the condensation characteristics of R134a with NCG and the thermodynamic parameters affecting condensation were studied.The results show that the section with relatively higher removal efficiency is usually near the inlet.The cold wall temperature has a great influence on the R134a removal performance,e.g.,a 15 K reduction of the wall temperature brings a reduction in the outlet R134a molar fraction by 85.43%.The effect of changing mass flow rate on R134a removal is mainly reflected at the outlet,where an increase in mass flow rate of 12.6% can aggravate the outlet molar fraction to 210.3% of the original.The research can provide a valuable reference for the simulation of the deep removal of various low-concentration gas using condensation and de-sublimation methods.
What problem does this paper attempt to address?