In-Situ Electrochemical Study on Susceptibility to Stress Corrosion Cracking of New-Developed 1200 MPa Ti-35421 Titanium Alloy

Zeng Qiangqiang,Qu Jiahui,Dan Zhenhua,Chang Hui,Zhou Lian
2023-01-01
Rare Metal Materials and Engineering
Abstract:The effects of different strain rates and cathodic protection potential on the stress corrosion cracking (SCC) behavior of new-developed 1200 MPa Ti-35421 (Ti-3Al-5Mo-4Cr-2Zr-1Fe) alloy were investigated by using slow strain rate test combined with in-situ electrochemical monitoring. The results indicate that Ti-35421 alloy has the highest SCC susceptibility in 3.5% NaCl solution at the strain rate of 1.67x10(-5) mm.s(-1). The plastic loss and stress corrosion index of Ti-35421 alloy are confirmed to be 27.27% and 0.273, respectively. The passivating ability of the passivation films in the crack tips is considered to be weaker than active dissolution under the combined interaction of applied stress and corrosive media especially with strain rate of 1.67x10(-5) mm.s(-1), which results in the intensification of SCC. When the cathodic protection potential is set at - 600 mV, the SCC susceptibility of Ti-35421 alloy in 3.5% NaCl solution is the lowest. The range of the optimal cathodic protection potential is measured to be from - 450 to - 600 mV. The reduction of the plastic loss and stress corrosion index of Ti-35421 alloy down to 1.01% and 0.113 is ascribed to the slower conjugated anodic reaction kinetics under the cathodic protection.
What problem does this paper attempt to address?