Heat Pipe Temperature Oscillation Effects on Solid-State Reactor Operation

Yugao Ma,Yicheng Zhao,Hongxing Yu,Shanfang Huang,Jian Deng,Xiaoming Chai
DOI: https://doi.org/10.1007/978-981-99-1023-6_29
2023-01-01
Abstract:The alkali metal heat pipes are the critical heat transfer elements in heat pipe cooled reactors. However, there are instabilities in heat pipes such as geyser boiling, resulting in temperature oscillation and even threatening the reactor safety. This work developed a coupled neutronic and thermal-mechanical analysis method to analyze the effects of geyser boiling and heat pipe temperature oscillations on the critical parameters, e.g., temperature and stress, during reactor operation. The megawatt heat pipe reactor MegaPower was chosen as an application case. The simulations show that the heat pipe temperature oscillation leads to the same frequency oscillation of the temperature and stress in the solid-state core. Besides, the temperature amplitudes are significantly reduced by shortening the oscillation period. Reducing the oscillation period from 60 s to 15 s reduced the temperature amplitude of the fuel pellet center from 22℃ to 5℃. Furthermore, the stress oscillation in the core may lead to material fatigue or even failure for a long period of operation, which is highly undesired. This work can provide valuable data and references for the safety design of heat pipe reactors.
What problem does this paper attempt to address?