Shear Behaviour of FRP-confined Concrete/uhpc Core-Encased Rebar: Experimental Investigation and Design Method

Li Hu,Peng Feng,Jia-Qi Yang,Zhiyuan Li
DOI: https://doi.org/10.1016/j.engstruct.2023.115951
IF: 5.582
2023-01-01
Engineering Structures
Abstract:FRP-confined concrete/UHPC (ultra-high-performance concrete) core-encased rebar (FCCC-R) is a recently developed novel structural component for FRP-concrete composite structures. FCCC-R utilization can improve both the strength and ductility of composite structural members under both axial compression and combined bending-compression loading. When implemented in vertical structural members such as columns and shear walls with a low shear-span ratio, FCCC-Rs are subjected to combined axial compression and shear. In this study, the shear behaviour of FCCC-Rs is experimentally investigated. A total of 28 FCCC-R specimens are tested. The failure mechanism and modes, the load-deflection curves and the ultimate strength were obtained from the experiments. The FCCC-Rs exhibited higher load capacity and deformability. It could be concluded that the combination of the FRP tube, concrete and rebar can achieve the effect of "1+1+1>3". Furthermore, the in-fluence of the shear-span ratio, concrete strength, tube thickness and fibre orientation are examined. Finally, design equations for the shear strength of FCCC-Rs are proposed, which attain a good agreement with the test data.
What problem does this paper attempt to address?