Low Temperature Hydrothermal Coupling of Ferrous Ion Activated Persulfate to Improve the Dewatering Performance of Waste Activated Sludge

SUN Qianqian,LIU Zhen,LI Rui,ZHANG Xi,YANG Mingde,WU Yulong
DOI: https://doi.org/10.16085/j.issn.1000-6613.2022-1837
2023-01-01
Abstract:Waste activated sludge with high moisture content challenges the harmless treatment and resource utilization of sludge.In this study,low temperature hydrothermal coupling Fe 2+ -activated persulfate was used to improve the dewatering performance of waste activated sludge.The results showed that when 0.75mmol/g DS Fe 2+ and 0.6mmol/g DS S 2 O 8 2- were added at 80℃,the molar ratio of Fe 2+ /S 2 O 8 2- was 1.25,capillary suction time (CST) of sludge decreased from 397.4s±7.9s to 18.9s±0.4s.It was found that in the process of activating persulfate with hydrothermal coupling Fe 2+ at low temperature to enhance the dewatering performance of sludge,the particle size of sludge first decreased and then increased,the extracellular polymer substance (EPS) was degraded,and the floc structure was damaged.The combination of heat and Fe 2+ accelerated the decomposition of persulfates to generate sulfate radicals(SO 4 ·- ) and hydroxyl radicals ( · OH) for oxidizing EPS,promoted the conversion of bound water into free water,and facilitated the solid-liquid separation of sludge.These studies provided a theoretical basis for dewatering sludge with low temperature hydrothermal coupling Fe 2+ -activated persulfate.
What problem does this paper attempt to address?