A Prospective Multicenter Study on the Additive Value of Contrast-Enhanced Ultrasound for Biopsy Decision of Ultrasound BI-RADS 4 Breast Lesions
Jun Luo,Lina Tang,Yijie Chen,Lichun Yang,Ruoxia Shen,Yan Cheng,Zizhen Zhang,Zhihong Lv,Lijun Yuan,Yong Yang,Yinrong Cheng,Baoyan Bai,Jing Luo,Qin Chen
DOI: https://doi.org/10.1016/j.ultrasmedbio.2024.04.010
2024-01-01
Abstract:OBJECTIVE:The main aim of this study was to determine whether the use of contrast-enhanced ultrasound (CEUS) could improve the categorization of suspicious breast lesions based on the Breast Imaging Reporting and Data System (BI-RADS), thereby reducing the number of benign breast lesions referred for biopsy.METHODS:This prospective study, conducted between January 2017 and December 2018, enrolled consenting patients from eight teaching hospitals in China, who had been diagnosed with solid breast lesions classified as BI-RADS 4 using conventional ultrasound. CEUS was performed within 1 wk of diagnosis for reclassification of breast lesions. Histopathological results obtained from core needle biopsies or surgical excision samples served as the reference standard. The simulated biopsy rate and cancer-to-biopsy yield were used to compare the accuracy of CEUS and conventional ultrasound (US).RESULTS:Among the 1490 lesions diagnosed as BI-RADS 4 with conventional ultrasound, 486 malignant and 1004 benign lesions were confirmed based on histology. Following CEUS, 2, 395, and 211 lesions were reclassified as CEUS-based BI-RADS 2, 3, and 5, respectively, while 882 (59%) remained as BI-RADS 4. The actual cancer-to-biopsy yield based on US was 32.6%, which increased to 43.4% when CEUS-based BI-RADS 4A was used as the cut-off point to recommend biopsy. The simulated biopsy rate decreased to 73.4%. Overall, in this preselected BI-RADS 4 population, only 2.5% (12/486) of malignant lesions would have been miscategorized as BI-RADS 3 using CEUS-based reclassification. The diagnostic accuracy, sensitivity, and specificity of contrast-enhanced ultrasound reclassification were 57.65%, 97.53%, and 38.35%, respectively.CONCLUSION:Our collective findings indicate that CEUS is a valuable tool in further triage of BI-RADS category 4 lesions and facilitates a reduction in the number of biopsies while increasing the cancer-to-biopsy yield.