The Feasibility and Efficacy of a Novel Nano Filter in Reducing the Hazards of Surgical Smoke Exposure During Gynecological Laparoscopic Surgery.

Xiaoxiao Feng,Bo Ding,Yang Shen
DOI: https://doi.org/10.1177/15533506231157169
2023-01-01
Surgical Innovation
Abstract:NEED:This study developed a nano-filter to reduce the concentration of hazardous substances in surgical smoke.METHODOLOGY AND DEVICE DESCRIPTION:The nano-filter consists of nanomaterials and hydrophilic materials. Smoke was collected before and after using the new nano-filter during the surgery.PRELIMINARY RESULTS:The concentration of PM2.5 and PAHs produced by the monopolar device was the highest (P < .05). The concentration of PM2.5 and PAHs after using a nano-filter was less than the non-filter group (P < .05).CURRENT STATUS:Surgical smoke generated by monopolar and bipolar devices pose a potential cancer risk to health staff in the operational room. The concentration of PM and PAHs were reduced and the cancer risk was not obvious by using the nano-filter.
What problem does this paper attempt to address?