Stress Self-Monitoring Performance of Grouted Sleeves with Smart Grout in Fabricated Reinforced Concrete Beams

Jiongfeng Sun,Guofu Qiao,Guangwei Ye
DOI: https://doi.org/10.1016/j.measurement.2022.112362
IF: 5.6
2023-01-01
Measurement
Abstract:Currently, grouted sleeves are widely used in the connection of prefabricated RC members. In this study, the smart grout with stress self-sensing performance was adopted to encapsulate grouted sleeves in which the structural and sensing functions are perfectly combined. Three parameters were investigated: grouted sleeve types, cycle index, and loading amplitude. In addition, a theoretical model was proposed to address the rela-tionship between the fractional change in resistance (FCR) and the vertical load. The results revealed that with the increase in the bending moment, the FCR of the smart grouted sleeves increased at the bottom of the RC beams. Moreover, the repeatability and stability of the stress self-monitoring performance decreased with the increase in the vertical pressure P, which was positively correlated with the residual value of the deflection. Then the agreement between the experimental and calculated FCR demonstrated the validity of the proposed model.
What problem does this paper attempt to address?