Study on Robust Absorption Performance of Hydrophilic Membrane Contactor for Direct Air Capture

Jian Sun,Peng Xu,Dawei Gong,Xiangli Kong,Kaiyun Fu,Xianfu Chen,Minghui Qiu,Yiqun Fan
DOI: https://doi.org/10.1016/j.seppur.2022.122978
IF: 8.6
2022-01-01
Separation and Purification Technology
Abstract:Increased atmospheric carbon dioxide (CO2) concentration constitutes a growing environmental and health concern. The absorption of CO2 from air requires a large gas-liquid contact area due to low driving force. Here, the membrane absorption was proposed to the removal of atmospheric CO2 using a ceramic membrane contactor, while NaOH serves as absorbent, performance of ceramic membrane absorption was study. In hydrophilic membrane, NaOH concentration of 2 mol center dot L-1 has the best absorption performance, which serves as initial concentration in absorption cyclic process, and when NaOH utilization reaches 75 %, it still has great absorption performance. In addition, suitable gas and liquid operating parameters of this work were also confirmed as 1000 mL center dot min(-1) and 1 mL center dot min(-1), respectively, corresponding mass transfer coefficient and CO2 absorption flux is 2.6 mm center dot s(-1) and 0.096 mol center dot m(-2)center dot h(-1), respectively. The great absorption stability shows the huge potential of ceramic membrane contactor application for direct air capture.
What problem does this paper attempt to address?