Biomechanical analysis before and after subtotal anterior cervical corpectomy with fusion to restore physiological curvature of the cervical spine with ossification of posterior longitudinal ligament
王小虎,郭媛,马五艳,张亚宁,李辉
DOI: https://doi.org/10.3760/cma.j.cn115668-20201125-00329
2021-01-01
Abstract:Objective:To build up a three-dimensional (3D) finite element model of subtotal anterior cervical corpectomy with fusion (ACCF) using softwares for digital modeling and finite element analysis based on reproduced abnormal physiological curvature of the cervical spine, and to validate the completed model by biomechanics computation with loadings, so as to provide guidance for proper surgical planning and prognostic evaluation in clinical settings.Methods:One patient in the Department of Spine Surgery of Linfen People’s Hospital was selected, of whom, 279 cervical spine images in DICOM format were imported into the Mimics modeling software to construct a preliminary 3D model in stl format. Using the Geomagic Studio 2013 software, the 3D model was smoothed, denoised, and simulated for ACCF in which the C 3 vertebral body and the upper and lower adjacent intervertebral discs were removed and replaced by a supporting titanium cage filled with bone fragments and secured with a six-hole titanium plate for anterior internal fixation. After C 3 corpectomy, the physiological curvature was adjusted so that the natural lordosis of straightened cervical spine was restored. After the adjustment, the Cobb angle was -10.76°. The model was further added with ligaments, intervertebral discs, and simulated facet joints, and imported into the finite element analysis software Ansys workbench 15.0 which then completed mesh generation, material attributes assignment, loading, and calculation of the stress at the cervical intervertebral disc and facet joints. Results:The 3D finite element model of ACCF was successfully constructed, including seven cervical vertebral bodies, three intervertebral discs, bilateral facet joints, and related ligaments. The internal fixation-fusion included one titanium cage, one titanium plate and four screws. The titanium cage was filled with cancellous bone fragments. The 3D model comprised 174 329 elements with a total of 398 325 nodes. The finite element calculation was done for the working condition in the case of anterior cervical flexion. The stress at C 1-C 7 facet joints were 4.29, 2.01, 1.95, 2.43, 0.54, and 0.69 MPa before surgery vs 3.33, 0.47, 0.79, 3.02, 0.63, and 0.26 MPa after surgery. Comparison on facet joint stress under two different working condition, five segments in the preoperative model presented higher facet joint stress than those in the postoperative model. In the post-surgical model, the stress of intervertebral disc at C 4-C 7 were 0.44, 0.66 and 0.46 MPa, respectively, which were lower than those in the pre-surgical model with straightening of physiological curvature. Conclusion:Using the real-world CT scan data of a patient, a finite element model with realistic appearance, highly-reproduced texture, and excellent geometric similarity was constructed and successfully validated. The biomechanical analysis suggests that restoration of physiological curvature of cervical spine can effectively reduce the stress to cervical disc and facet joints, which may help delay or prevent cervical degeneration later in life.