Determination of Energy Partition of a Cucumber Grown Venlo-type Greenhouse in Southeast China

Haofang Yan,Shuaishuai Deng,Chuan Zhang,Guoqing Wang,Shuang Zhao,Mi Li,Shaowei Liang,Jianhui Jiang,Yudong Zhou
DOI: https://doi.org/10.1016/j.agwat.2022.108047
IF: 6.7
2023-01-01
Agricultural Water Management
Abstract:Accurate determination of energy partition inside greenhouses is a key procedure in optimizing efficient water management. In this study, micro-meteorological data and energy fluxes of cucumber were measured during four planting seasons (2018-2021) in a Venlo-type greenhouse to analyze the energy manifestation in different growing stages. The results showed that the latent heat flux (lambda ET) was the primary component of net radiation (R-n), accounting for 61.2-72.6 % of R-n during the whole growing seasons, followed by sensible heat flux (H, 19.8-24.3 % of R-n) and soil heat flux (G, 7.6-14.8 % of R-n). The lambda ET increased while both H and G decreased as the crop grew. Especially, H was larger than lambda ET at midday in the initial growing stage. Energy partition was intensely affected by the leaf area index (LAI). The lambda ET/R-n increased linearly with the increase in LAI, while the H/R-n decreased linearly and G/R-n decreased exponentially until LAI reached 4 m(2) m(- 2). Canopy conductance (G(c)), Priestley-Taylor coefficient (alpha), and the decoupling coefficient (Omega) were calculated to evaluate the controlling factors over cucumber lambda ET. The high values of the alpha (= 1.15 +/- 0.05) and the Omega (= 0.65 +/- 0.05) indicated that the cucumber lambda ET was principally constrained by R-n. The G(c) was calculated by inverting Penman-Monteith (PM) equation using aerodynamic conductance (G(a)) values obtained by the heat transfer coefficient (h(s)) method based on accurate convection regimes. The G(c) varied from 1.42 to 17.98 mm s(-1) and high G(c) values corresponded to high lambda ET. The lambda ET was estimated by the Omega model with the mean root mean square error (RMSE) and mean absolute error (MAE) equaled 32.65 and 25.73 W m(-2), while the determination coefficient (R-2) was 0.94. The H was reproduced by the Bulk Transfer (BT) model to validate G(a) with the RMSE and MAE equaled 32.57 and 24.95 W m(-2), the R-2 was 0.86. The results also indicated that the simplified energy balance (EB) method was an optional approach to analyzing energy partition in greenhouses. Consequently, more energy could be saved by avoiding the excessive application of water and thus improving crop water use efficiency in greenhouses.
What problem does this paper attempt to address?