High-intensity ultrasound catheter ablation achieves deep mid-myocardial lesions in vivo

Babak Nazer,David Giraud,Yan Zhao,James Hodovan,Miriam R Elman,Ahmad Masri,Edward P Gerstenfeld,Jonathan R Lindner,Miriam R. Elman,Edward P. Gerstenfeld,Jonathan R. Lindner
DOI: https://doi.org/10.1016/j.hrthm.2020.12.027
IF: 6.779
2021-04-01
Heart Rhythm
Abstract:<h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Background</h3><p>Radiofrequency (RF) ablation of epicardial and mid-myocardial ventricular arrhythmias (VAs) is limited by lesion depth.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Objectives</h3><p>To generate deep, mid-interventricular septal (IVS) lesions using high-intensity ultrasound (US) from an endocardial catheter-based approach.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Methods</h3><p>Irrigated US catheters (12 Fr) were fabricated with 3x5 mm transducers of 5.0, 6.5 and 8.0 MHz frequencies, and compared in an <em>ex vivo</em> perfused myocardial ablation model. <em>In vivo</em> septal ablation in swine (n=12) was performed via femoral venous access to the right ventricle. Lesions were characterized by echocardiography, cardiac MRI and electroanatomic voltage mapping pre- and post-ablation, and at 30 days. Four animals were euthanized immediately post-ablation to compare acute and chronic lesion histology and gross pathology.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Results</h3><p>In <em>ex vivo</em> models, maximal lesion depth and volume was achieved by 6.5 MHz catheters, which were used <em>in vivo</em>. Lesion depth by gross pathology was similar post-ablation (10.8[95% CI:9.9,12.4] mm) and at 30 days (11.2[CI:10.6,12.4] mm, p=0.56). Lesion volume decreased post-ablation to 30 days (255[CI:198,440] to 162[CI:133,234] mm<sup>3</sup> p=0.05), yet transmurality increased 58%(CI:50,76) to 81%(CI:74,93), attributable to a reduction in IVS thickness (16.0±1.7 to 10.6±2.4 mm, p=0.007). MRI confirmed dense septal ablation by delayed enhancement, with increased T1 time post-ablation and at 30 days, and increased T2 time only post-ablation. Voltage mapping of both sides of IVS demonstrated reduced unipolar (but not bipolar) voltage along the IVS.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Conclusions</h3><p>High-intensity US catheter ablation may be an effective treatment for mid-myocardial or epicardial VAs from an endocardial approach.</p>
cardiac & cardiovascular systems
What problem does this paper attempt to address?