Optical Filter Selection for Photoacoustic Sensors of Multicomponent Gases: Considering Cross-Interference

Zhicheng Wu,Fangji Liu,Yizhou Jiao,Chenyang Wang,Xiang Li,Qiaogen Zhang
DOI: https://doi.org/10.1109/tim.2023.3304691
2022-01-01
Abstract:Cross interference among multicomponent gases largely limits the further improvement of the detection performance of photoacoustic gas sensors. The selection of optimal optical filters has become a key challenge for reducing the cross interference and ensuring the sensitivity of the sensors. Taking cross interference of CH4 by hydrocarbon gases and carbon oxides dissolved in transformer oil as an example, this study proposed an optical filter selection method applicable for detecting multicomponent gases, from both quantitative calculation and experimental verification. Quantitative calculation results showed that sensitivity and cross interference were contradictory parameters for CH4 gas detection. Experimental examinations of sensitivity, cross interference, limit of detection (LOD), and prediction performance showed that an optical filter with a central wavelength (CW) of 7720 nm and full-width at half-maximum (FWHM) of 480 nm can achieve better performance than an optical filter with a CW of 8100 nm and FWHM of 230 nm. Also, considering the spectral characteristics of optical filters, windows, and light sources effectively reduced the deviation between theoretical calculation and experimental results. The optical filter selection method proposed here was of great significance for constructing photoacoustic sensors of multicomponent gases and provided a theoretical basis to improve the detection performance of photoacoustic gas sensing systems.
What problem does this paper attempt to address?