IMPROVING THE FILM COOLING BY CONTROLLING THE VORTEX STRUCTURES

Qiuyin Wang,Mostafa Moosania,Chao Zhou
DOI: https://doi.org/10.33737/gpps21-tc-19
2022-01-01
Abstract:For film cooling, vortex structures downstream of the cooling hole determine the coolant mixing and the coverage surface area. The current study aims at identifying the vortex structures that can result in favorable cooling performance, based on which new holes are designed. The crescent hole with the convex leading edge can produce vortex structures that combine the features of two compound angle cylindrical holes and a middle vortex structure. These vortex structures prevent the coolant from lifting off from the surface at both low and high blowing ratios, and can result in uniform cooling effectiveness covering a larger area comparing to the cylindrical hole. To further improving cooling, another cooling hole is used to remove two small vortices on the lateral side by changing the up-convex to a down-convex crescent hole. This changes the rotational direction of the shear layer vortex at the lateral side of the hole, and produces a corotate vortex structure with the main anti-counter rotating vortex pair (anti-CRVP) which further enhances surface cooling effectiveness.
What problem does this paper attempt to address?