Experimental analysis of pressure deviation-induced film cooling effectiveness deviation in pressure sensitive paint measurement
Yuzhu Lou,Haiwang Li,Zhiyu Zhou,Jinghan Zhang,Yuan Yue,Zhi Tao,Gang Xie
DOI: https://doi.org/10.1016/j.ijheatmasstransfer.2024.126306
IF: 5.2
2024-10-22
International Journal of Heat and Mass Transfer
Abstract:The use of the Pressure Sensitive Paint (PSP) measurement method allows for obtaining dense, completely adiabatic film cooling effectiveness ( η ) results. In order to adapt to the increasing trend of high-speed and complexity in the application scenarios of film cooling, the pressure deviation-induced film cooling effectiveness deviation in PSP measurements needs to be quantified and corrected. Initially, two different jets of specific materials were injected into a dual-hole flat plate test piece. The pressure difference at corresponding positions of the two jet flows was measured to demonstrate that, compared to air, a ternary oxygen mixed gas better simulated the pressure field of the foreign gas. This illustrates the feasibility of the Test3-OM correction method. Building upon this, the influence of pressure deviation on the accuracy of measurement results was quantitatively evaluated in various scenarios, including a flat circular hole, film holes with a compound angle, a converging slot hole, and film holes at three positions on the blade. The results indicate that the pressure deviation-induced η deviation is non-negligible under conditions of high blowing ratios in most positions. Particularly in the low η region, there is a higher sensitivity to pressure deviation. Generally, there is a negative deviation region near the hole downstream, and a positive deviation region slightly downstream. The generation of deviations stems from variations in density, resulting in different flow patterns of the jet near the wall surface.
engineering, mechanical,thermodynamics,mechanics