Abstract:The three-dimensional anodes for SO2 depolarized electrolysis (SDE) cells are prepared by loading Pt/C on high void content graphite felts, with the method of ultrasonic spray and vacuum suction. SEM results confirm the three-dimensional space distribution of Pt in graphite felts, which ensures sufficient contact between Pt/C and SO2 in anolyte. Comparing with the two-dimensional anodic catalyst layer loaded on the proton exchange membrane in a conventional SDE cell, the application of the three-dimensional anode decreases cell impedance greatly and improves the SDE performance significantly. In this study, 0.63 mg/cm(2) Pt loading amount shows the best performance when Pt/C is double-side-sprayed on graphite felt, and the current density reaches 1.24 A/cm(2) at cell voltage of 1.2 V, as operating at 60 ? and anolyte flow rate of 360 mL/min. The effects of the Pt loading amount, operating temperature and anolyte flow rate on the SDE performance are investigated. (C) 2022 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.