Progress on the Development of the Collinear Laser Spectroscopy Setup for the Study of Unstable Nuclei
Peng Zhang,Yinshen Liu,Shiwei Bai,Xiaofei Yang,Shujing Wang,Yongchao Liu,Hanrui Hu,Yangfan Guo,Zheyang Lin,Zhou Yan,Zeyu Du,Wencong Mei,Yanlin Ye,Qite Li
DOI: https://doi.org/10.1360/tb-2022-1116
2022-01-01
Abstract:The basic properties of unstable nuclei are very sensitive probes for the study of exotic nuclear structures, which is of importance for an in-depth understanding of the unexpected structure phenomena in atomic nuclei with large proton-toneutron ratios. Collinear laser spectroscopy (CLS) techniques have been proven to be a powerful tool to determine simultaneously multiple fundamental properties of ground and long-lived isomeric states of exotic nuclei, such as nuclear spins, electromagnetic moments and charge radii, by measuring the subtle hyperfine structure and isotope shifts in a nuclear model-independent manner. The studies of nuclear properties and structures of unstable nuclei using laser spectroscopy have been broadly carried out at ISOL (Isotope Separator On-Line)-type radioactive ion beam (RIB) facilitates, such as ISOLDE at CERN, IGISOL at JYFL and ISAC at TRIUMF, where the low energy RI beam is directly offered with highquality. With the goal to explore more exotic nuclei, laser spectroscopy techniques, with their continuous technological development towards higher resolution and higher sensitivity, have been broadly established and planned at current- and next-generation RIB facilities worldwide. This CLS technique, however, has not yet been implemented at current operational domestic RIB facilities, the PF (Projectile Fragmentation)-type HIRFL at IMP and the BRIF (ISOL-type) at CIAE, for the studies of nuclear properties of unstable nuclei. Thus, we have recently developed a fluorescence-detection-based CLS system, which has been commissioned with stable ion beam produced from an offline laser ablation ion source and radioactive ion beam from BRIF RIB facility. In this paper, we briefly introduce the recent progress on the development of laser spectroscopy techniques at RIB facilities worldwide, as well as the experimental methods to measure the hyperfine structure spectra. Subsequently, the details of the CLS system recently developed, are presented together with recent upgrades and offline test. The optimization and upgrade of this system, include the lens rotator system for laser spot control, ion beam imaging using a phosphor screen, and calibration of the neutralization efficiency of the change exchange process. Based on these upgrades, we performed the offline test experiment using stable Ca and Ti beams. The optical spectra for the 4s S-2(1/2) -> 4p (2) P-3/2 ionic transition of Ca-40(+) and for the 3d(2)4s(23)F(2) -> 3d(3) 4p (3) D-1 atomic transition of Ti-48 were obtained, giving a spectral linewidth of approximately 55 MHz for Ca and 65 MHz for Ti. The total detection sensitivity estimated in the case of Ca-40(+) is comparable to that of the well-established CLS setups worldwide. Finally, a summary and outlook on the further development of the collinear resonance ionization spectroscopy towards higher sensitivity are given, which will be used at the current and future RIB facilities in China for the study of unstable nuclei with shorter half-lives and lower production yield. Further implementation of the UCx target into the BRIF facility is currently on-going, which will potentially produce more exotic isotopes at different mass regions. Development and installation of a radiofrequency quadrupole cooler and buncher are also on-going, which could provide bunched ion beams with low energy spread of few electron volts, being essential for the high resolution and high sensitivity measurement of unstable nuclei using CLS.