Electrical Characteristics of High-Performance Ultrasonic Transducer for Non-Destructive Testing
Juhyun Yoo,Sujin Kang,Jonghyeon Lee,Jaekyu Lee,Sun A. Whang,Suho Lee,Seonghoon Kee
DOI: https://doi.org/10.1007/s42341-023-00432-0
2023-02-19
Transactions on Electrical and Electronic Materials
Abstract:To develop an ultrasonic transducer for non-destructive testing, PNN-PZT-PMW-system ceramics were manufactured using the columbite method. The microstructural, dielectric, and piezoelectric properties of these ceramics were investigated. For the specimen sintered at 920 ◦ C, the dielectric constant (ε r ), piezoelectric coefficient (d 33 ) planar electromechanical coupling factor(k p ), mechanical quality factor(Q m ), and piezoelectric voltage constant(g 33 ) were 1,773, 465[pC/N], 0.62, 44 and 29.6[mV⋅m/N], respectively, with a high Curie temperature (T c ) of 295 ◦ C. These values are suitable for application of the ceramics to devices such as ultrasonic transducers. Ultrasonic transducers with ceramics of various dimensions were manufactured using the developed composition, and their electrical properties were investigated. The Ut-1 ultrasonic transducer was most suitable for detecting defects in concrete because its maximum sensitivity at 29.41 kHz was 87.32 dB and its sensitivity at 50 kHz was 65.99 dB.