Clinical analysis of prostate targeted biopsy guided by multiparametric magnetic resonance imaging and 68Ga-PSMA PET/CT image fusion

林国文,戴波,叶定伟,刘畅,朱耀,秦晓健,王弘恺
DOI: https://doi.org/10.3760/cma.j.cn112330-20220510-00273
2022-01-01
Abstract:Objective:To explore clinical value of prostate target biopsy guided by multiparametric magnetic resonance imaging (mpMRI) and 68Ga-labeled prostate specific membrane antigen ligand imaging positron emission tomography/X-ray computed tomography ( 68Ga-PSMA PET/CT) image fusion. Methods:The data of 50 patients admitted to Fudan University Shanghai Cancer Center from January 2021 to February 2022 who underwent mpMRI and 68Ga-PSMA PET/CT to guide prostate biopsy were retrospectively analyzed. The median age was 70 (63-79) years, the median serum tPSA value was 8.1 (6.8-83.0) ng/ml, and the prostate volume was 45.5 (30-80) ml. 36 cases were positive by mpMRI, including PI-RADS score 3 in 5 cases, 4 score in 19 cases, 5 score in 12 cases. 32 cases were positive by 68Ga-PSMA PET/CT examination, of which 30 cases were double positive and the fusion of both imaging techniques was positive, referred to as PET/CT-MRI. The patient's mpMRI and 68Ga-PSMA PET/CT images were imported into the MIM fusion software, and the outline of the prostate and the target area were outlined respectively. When PET/CT and MRI double positive cases were biopsied, the two images were alternately fused, calibrated and locked with the real-time prostate ultrasound interface(PET/CT-MRI). Single-positive cases were guided by positive images to complete targeted biopsy, and 12-needle systematic biopsies were completed after targeted biopsy and double-negative cases. The advantages of targeted biopsy and systematic biopsy was evaluated, and the diagnostic performance (sensitivity, specificity, positive predictive value, and negative predictive value) was analyzed. Results:Among the 50 biopsy patients in this group, 31 (62%) had prostate cancer, of which 22 (44%) were CsPCa. There was no significant difference in the detection rate of prostate cancer between targeted biopsy and systematic biopsy [78.9% (30/38) and 62.0% (31/50), P=0.088], and there was no significant difference in the detection rate of CsPCa [57.9% (22/38) and 40.0% (20/50), P=0.096]. The positive rate of the biopsy needles number was significantly different [86.3% (69/80) and 19.0% (114/ 600), P<0.001]. The detection rates of prostate cancer in mpMRI positive, PET/CT positive and PET/CT-MRI positive cases were 83.3% (30/36), 90.6% (29/32) and 96.6% (29/30) respectively, the detection rates of CsPCa were 61.1% (22/36), 68.8% (22/32) and 73.3% (22/30) respectively.The sensitivity, specificity, positive predictive value and negative predictive value of mpMRI in the diagnosis of prostate cancer were 96.8%(30/31), 68.4%(13/19), 83.3%(30/36)and 92.9%(13/14), respectively.Those values in 68Ga-PSMA PET/CT were 93.5%(29/31), 84.2%(16/19), 90.6%(29/32)and 88.9%(16/18), respectively.Those values in PET/CT-MRI were 93.8%(29/31), 94.7%(18/19), 96.7%(29/30)and 90.0%(18/20), respectively. The above four indicators of mpMRI diagnosis of CsPCa were 100.0%(22/22), 50.0%(14/28), 61.1%(22/36)and 100.0%(14/14), respectively.Those indicators in 68Ga-PSMA PET/CT were 100.0%(22/22), 64.3%(18/28), 68.8%(22/32)and 100.0%(18/18), respectively.Those indicators in PET/CT-MRI was 100.0%(22/22), 71.4%(20/28), 73.2%(22/30)and 100.0%(20/20), respectively. The detection efficiency of PET/CT-MRI was better than that of mpMRI (Kappa value was 0.737, P=0.031). Conclusions:PET/CT-MRI image fusion-guided targeted prostate biopsy can effectively improve the detection efficiency of prostate cancer and clinically significant prostate cancer, and increase the positive rate.
What problem does this paper attempt to address?