Plif Experiment and Verification of Boron Mixed Diffusion Model Driven by Turbulence in Nuclear Reactor

Xinyu Zhang,Hui Yang,Yuncong Ding,Bing Dong,Yuchen Song,Wentao Zhou,Dezhong Wang
DOI: https://doi.org/10.1016/j.anucene.2023.109682
IF: 1.9
2023-01-01
Annals of Nuclear Energy
Abstract:10B has a large neutron absorption cross section and is commonly used as a neutron poison in the light water reactor (LWR) to adjust the reactivity of nuclear reactors. In this paper, for the first time, a new planar laser-induced fluorescence (PLIF) method with sodium fluorescein as the tracer is used to measure the concentra-tion field of boric acid. In this paper, the injection process is abstracted as a T-tube. The accuracy of LIF is verified by wire mesh sensor. The CFD method is used to simulate the mixing process to come up with proper parameters to consider the influence of turbulence on the flow. The branch velocity of T-tube has a great influence on the diffusion process. The mixing process in the pipeline is mainly driven by turbulence of the side jet. Boric acid is evenly mixed in the pipe within 8 similar to 10 times of the pipe diameter.
What problem does this paper attempt to address?