Mathematical model of Chinese reference human based on the standards of Chinese Reference individuals for use in radiation protection

王震涛,杨翊方,王海军,张凯,马丽
DOI: https://doi.org/10.3760/cma.j.cn311847-20210228-00068
2022-01-01
Abstract:Objective:To construct a mathematical model of Chinese reference human of medical internal radiation dose(CRH-MIRD)for use in radiation protection in accordance with the physical features of Chinese adult males.Methods:Based on the data from the Chinese Reference individuals for use in radiation protection(GBZ/T 200),and referring to the Data of Anatomical Physiological and Metabolic Characteristics for Chinese Reference Man and the data of Asian Reference Man,the CRH-MIRD model was constructed by zooming and adjusting the MIRD used in Europe and America. Under different radiation ways with different radiation energy,the radiation absorbed dose conversion coefficients of main tissues and organs and the whole-body effective dose conversion coefficients of the CRH-MIRD model were calculated by the Monte Carlo method. These coefficients were then compared and validated with those of the authoritative publication,and the coefficients calculated by MIRD model and voxel model,respectively.Results:The differences between the dose conversion coefficients calculated by the CRH-MIRD and MIRD models could basically reflect the differences of anatomical data between the Chinese reference man and the reference man in Europe and America. The coefficients calculated by the voxel model differed significantly from those in the above two models,due to the voxel model adopted different modeling method and data of reference man.Conclusion:Based on the data of Chinese reference individuals,the CRH-MIRD model,established by the internationally recognized idea and methods of constructing a mathematical model of human body for use in radiation protection,has calculated reasonable and credible results.
What problem does this paper attempt to address?