Diagnostic performance of smart watch electrocardiograph in detecting atrial fibrillation episodes in patients with different ventricular rates

陈婉岚,黄嘉慧,施盈,邱朝晖
DOI: https://doi.org/10.3760/cma.j.cn113859-20220411-00068
2022-01-01
Abstract:Objective:To evaluate the diagnostic performance of the Apple Watch electrocardiograph(ECG) in detecting atrial fibrillation(AF) episodes in patients with different ventricular rates.Methods:This study was conducted in Tongren Hospital, Shanghai Jiao Tong University School of Medicine between July 1, 2019 and March 3, 2021.Patients with AF or sinus rhythm were enrolled.Patients underwent a 12-lead ECG along with an Apple Watch ECG.The enrolled patients were divided into three groups (group A: ventricular rate below 60 bpm; group B: ventricular rate between 60 and 100 bpm; group C: ventricular rate above 100 bpm) according to the rhythm of the 12-lead ECG.All records of 12-lead ECG and Apple Watch ECG were interpreted by the electrophysiologist.The results of the 12-lead ECG interpreted by electrophysiologists were taken as the gold standard.The sensitivity, specificity, and K coefficient of the Apple Watch ECG rhythm algorithm to detect AF in patients with different ventricular rates were measured.In addition, the sensitivity, specificity and K coefficient of the Apple Watch ECG recordings interpreted by electrophysiologists for detecting AF in patients with different ventricular rates were also measured. Results:A total of 248 patients were enrolled, 122 were male, and the mean age was (74.25±11.67) years old.One hundred and twenty nine patients were diagnosed with sinus rhythm by the electrophysiologist interpretation according to 12-lead ECG, and 119 patients were diagnosed with AF.Compared with 12-lead ECG, the rhythm algorithm of Apple Watch ECG was 81.80%, 63.83% and 68.75% sensitive for detecting AF and a specificity of 100%, 100% and 100% in Group A, B, C (Group A including 41 patients, Group B including 163 patients, Group C including 44 patients; Kappa=0.98, 0.70 and 0.55) respectively.The electrophysiologist interpretation of Apple Watch ECG recordings diagnosed AF with a sensitivity of 100.00%、88.20%、93.80%, and a specificity of 100%, 100% and 100% in Group A, B, C ( Kappa =1.00, 0.88, 0.89) respectively.The Apple Watch ECG recordings interpreted by the electrophysiologist had a higher sensitivity than the rhythm algorithm of Apple Watch ECG in detecting AF. Conclusion:The rhythm algorithm of Apple Watch ECG application to detect AF still needs a further improvement.The Apple Watch ECG has a better diagnostic performance in detecting AF episodes in patients with low ventricular rate.In order to improve the diagnostic performance, Apple Watch ECG recordings would be more reliable when interpreted by the electrophysiologist.
What problem does this paper attempt to address?