Reproducibility of 3 T APT‐CEST in Healthy Volunteers and Patients with Brain Glioma

Ivar J. H. G. Wamelink,Joost P. A. Kuijer,Beatriz E. Padrela,Yi Zhang,Frederik Barkhof,Henk J. M. M. Mutsaerts,Jan Petr,Elsmarieke van de Giessen,Vera C. Keil
DOI: https://doi.org/10.1002/jmri.28239
2022-01-01
Abstract:BackgroundAmide proton transfer (APT) imaging is a chemical exchange saturation transfer (CEST) technique offering potential clinical applications such as diagnosis, characterization, and treatment planning and monitoring in glioma patients. While APT‐CEST has demonstrated high potential, reproducibility remains underexplored.PurposeTo investigate whether cerebral APT‐CEST with clinically feasible scan time is reproducible in healthy tissue and glioma for clinical use at 3 T.Study TypeProspective, longitudinal.SubjectsTwenty‐one healthy volunteers (11 females; mean age ± SD: 39 ± 11 years) and 6 glioma patients (3 females; 50 ± 17 years: 4 glioblastomas, 1 oligodendroglioma, 1 radiologically suspected low‐grade glioma).Field Strength/Sequence3 T, Turbo Spin Echo ‐ ampling perfection with application optimized contrasts using different flip angle evolution ‐ chemical exchange saturation transfer (TSE SPACE‐CEST).AssessmentAPT‐CEST measurement reproducibility was assessed within‐session (glioma patients, scan session 1; healthy volunteers scan sessions 1, 2, and 3), between‐sessions (healthy volunteers scan sessions 1 and 2), and between‐days (healthy volunteers, scan sessions 1 and 3). The mean APTCEST values and standard deviation of the within‐subject difference (SDdiff) were calculated in whole tumor enclosed by regions of interest (ROIs) in patients, and eight ROIs in healthy volunteers—whole‐brain, cortical gray matter, putamen, thalami, orbitofrontal gyri, occipital lobes, central brain—and compared.Statistical TestsBrown‐Forsythe tests and variance component analysis (VCA) were used to assess the reproducibility of ROIs for the three time intervals. Significance was set at P < 0.003 after Bonferroni correction.ResultsIntratumoral mean APTCEST was significantly higher than APTCEST in healthy‐appearing tissue in patients (0.5 ± 0.46%). The average within‐session, between‐sessions, and between‐days SDdiff of healthy control brains was 0.2% and did not differ significantly with each other (0.76 > P > 0.22). The within‐session SDdiff of whole‐brain was 0.2% in both healthy volunteers and patients, and 0.21% in the segmented tumor. VCA showed that within‐session factors were the most important (60%) for scanning variance.Data ConclusionCerebral APT‐CEST imaging may show good scan–rescan reproducibility in healthy tissue and tumors with clinically feasible scan times at 3 T. Short‐term measurement effects may be the dominant components for reproducibility.Level of Evidence2Technical EfficacyStage 2
What problem does this paper attempt to address?