Research on the ring strain of the segment for large-section underwater shield tunnels
Rongjun Xing,Chao Tang,Chuan He,Kun Feng,Shengya Xu,Zhengshu He,Daiqiang Zhu,Pai Xu
DOI: https://doi.org/10.1007/s13349-024-00854-1
2024-11-16
Journal of Civil Structural Health Monitoring
Abstract:The underwater shield tunnel, as a critical engineering project spanning rivers and seas, has entered a phase of rapid development. However, the large-section underwater shield tunnel faces significant challenges due to the complexity of its geological and hydrological environment, which subjects it to high load conditions, such as water and earth pressures. These challenges pose severe risks to the structural safety of the tunnel and substantially compromise traffic safety. Consequently, the investigation of tunnel segment structures has emerged as a key area of research. Traditional studies have often focused on the elastic or failure stages of the segments, neglecting the deformation characteristics of the segments under various stress states throughout their operational lifespan. This study employs full-scale testing methods alongside fiber Bragg grating (FBG) sensing technology to gather elastic strain data from the tunnel segments under varying conditions, including earth pressure, water pressure, lateral pressure coefficients, and the positioning of sealing blocks. Additionally, it analyzes strain data during the micro-cracking and damage phases, exploring the circumferential strain patterns that arise. In contrast to numerical simulations or scaled model tests, full-scale testing allows for direct observation and measurement of the deformation and failure processes of the tunnel segments under realistic engineering conditions, thereby providing a more accurate representation of actual conditions and enhancing the reliability of the research findings. The results indicate that elevated water pressure significantly reduces the circumferential strain of the tunnel segments, thereby decreasing the degree of structural deformation. An increased lateral pressure coefficient also markedly mitigates these effects. To ensure the structural safety of cracked tunnel segments, vertical ground pressure must not exceed 4 MPa when water pressure is at 40 m and the lateral pressure coefficient is 0.5. Furthermore, under hydraulic loads of 80 m, if vertical earth pressure exceeds 14.7 MPa, a stress redistribution occurs, causing the arch bottom strain to transition to a compressive state. Thus, the industry can utilize the deformation characteristics of segments at various stages presented in this study to optimize design parameters, formulate targeted maintenance strategies, and prevent structural damage, thereby ensuring the safety of tunnel structures and extending their service life.
engineering, civil