Enhanced Electro-Fenton Degradation of Ciprofloxacin by Membrane Aeration

Keda Zhi,Chao Yang,Yu Zheng,Runnan Zhang,Omojayogbe E. Toyosi,Hong Wu,Zhongyi Jiang
DOI: https://doi.org/10.1021/acs.iecr.2c00857
2022-01-01
Industrial & Engineering Chemistry Research
Abstract:Electro-Fenton is a widely used electrochemical advanced oxidation process for the treatment of refractory organic pollutants, in which O-2 input is required to generate hydrogen peroxide. The aeration mode directly affects the dissolution and stability of O-2 bubbles in the solution, thus the rate of degradation. Herein, membrane aeration was introduced to the electro-Fenton degradation of ciprofloxacin in which O(2 )was dispersed into the liquid phase in the form of microbubbles through the ceramic membrane. Microbubbles can greatly improve the gas-liquid mass transfer efficiency of unit volume O-2 to obtain an ultrahigh concentration of dissolved O-2 up to 46 mg/L, thus improving the reaction rate. The effects of aeration mode, applied current, membrane aperture, aeration rate, and ciprofloxacin concentration on degradation rate were studied. Compared with the conventional electro-Fenton process using plastic pipe aeration, the membrane aeration-enhanced electro-Fenton (MAEF) system achieved a significant improvement in the degradation rate, and the reaction time required to achieve a 97% degradation ratio was remarkably reduced from 4 h to 10 min. Membrane aeration is an efficient approach to facilitating heterogeneous catalysis reactions involving the gas phase.
What problem does this paper attempt to address?